July 09,2026
1. In high‑speed applications, if measured temperature rise exceeds 70°C, switch to a machined cage.
2. Temperature: material property vs. temperature curves are openly available.
3. Hand‑rotating noise: “clicking” sounds indicate pocket wear – shorten relubrication intervals.